Introduction
The Wondrwall Thermostat is a battery-powered ZigBee device that controls heating and cooling systems. It provides manual operation via its LCD display and +/– buttons, as well as remote control through the Wondrwall app.
Correct installation is important for reliable communication, accurate temperature control, and long battery life.
This article provides step-by-step instructions for qualified electricians to install the Wondrwall Thermostat.
Safety & Compliance
Caution: This product must only be installed by qualified electricians.
-
Isolate the heating/cooling circuit and the boiler or heat source before beginning work. Some circuits do not isolate the boiler, and live parts may remain energised.
-
Regulatory compliance: follow BS7671 wiring regulations and all relevant building codes.
-
PPE: use safety glasses, insulated gloves, and a dust mask. Hearing protection may be required if drilling into masonry.
-
Batteries: only use 2× AA alkaline batteries (supplied). Do not use rechargeable or “heavy-duty” batteries.
Before You Begin
Prerequisites:
-
Heating/cooling system wiring is accessible at the chosen location.
-
ZigBee coverage available from the master Wondrwall Light Switch.
Tools required:
-
Insulated screwdriver set.
-
Voltage tester.
-
Drill and wall plugs (if mounting on masonry).
Installation Steps
Step 1: Prepare the Location
-
Choose a central wall position in the zone, between 1.2 m and 1.5 m above floor level (1.2 m if accommodating wheelchair users).
-
Avoid placing above radiators, near doors/windows, or in direct sunlight.
Step 2: Wire the Thermostat
-
The thermostat contains a 230V, 5A relay (check relay spec before wiring).
-
Normally, only two relay terminals are used: COM and NO (Normally Open).
-
Connect the heating/cooling system wiring through the central opening on the back cover to the correct relay terminals.
-
Ensure insulation is intact and no bare copper is exposed.
-
Mark and secure wiring clearly for handover.
Step 3: Mount the Back Cover
-
Use the mounting holes on the back cover as a template to mark the location.
-
Drill holes, insert wall plugs if required, and secure the back cover with screws.
-
Ensure the back cover is flush and secure.
Step 4: Insert Batteries
-
The battery compartment is accessible on the back cover.
-
Insert 2× AA alkaline batteries observing correct polarity.
-
You do not need to remove anything further once the back cover is fitted.
Step 5: Fit the Thermostat Body
-
Replace the front face/main body of the thermostat onto the back cover.
-
Ensure the two prongs slot correctly into their housing points.
-
Press gently until the body clicks securely into place.
Step 6: Removing the Thermostat Body (if required)
-
To remove the front face/main body from the back plate:
-
Locate the two vertically aligned clips on either side of the unit.
-
Squeeze both clips gently.
-
While holding the clips, pull the front face away from the backing plate in a smooth motion.
-
-
Take care not to lever with tools or force the clips, as this may damage the housing.
Verification
After installation:
-
The thermostat will always power on if batteries are present.
-
Enable the heating circuit and the end heating device (e.g. boiler).
-
On the LCD, check for the heat icon. When the thermostat calls for heat:
-
The relay clicks.
-
The end device fires up.
-
-
Test manual control:
-
Tap the + button once per second to increase setpoint.
-
Tap the – button once per second to decrease setpoint.
-
Avoid holding buttons down, as this can confuse the device.
-
Common Installation Errors to Avoid
-
Mounting in direct sunlight or above a radiator.
-
Incorrectly wired relay terminals (COM/NO/NC).
-
Using rechargeable or heavy-duty batteries.
-
Loose mounting leading to poor contact between prongs and housing.
Handover to Wondrwall Engineer
Before leaving site:
-
Confirm the thermostat powers on with the LCD active.
-
Demonstrate that a call for heat displays the heat icon, activates the relay, and fires the end device.
-
Provide wiring details and confirm battery type used.